30C
Offering first-class comfort in a compact, wall-hung appliance small enough to fit inside a standard kitchen cupboard*, the Keston 30C combination boiler enables heating and hot water to be controlled independently, ensuring maximum comfort and efficiency.
The Keston C30 combination boiler can be sited almost anywhere in the home, without the need for a separate tank. And because it connects to the unique Keston twin-flue system, the boiler can be situated anywhere up to 21 metres from the flue outlet, helping to provide further flexibilit y when required.
Fully modulating, the 30C provides excellent energy savings, making it the perfect choice for new or replacement installations alike.
*Please check cupboard size prior to installation
-
High efficiency
-
Compact cupboard fit for neat installations
-
Door to optional timer includes users instructions
-
Preheat function for fast response times
-
Twin flue option
-
Low lift weight for easier installation
-
Preformed copper tails
-
Pre-wired mains lead (2m) & spare fuses included
-
Built-in frost protection
-
Weather compensation as standard
-
Three year parts and labour warranty
Performance Data
Central Heating (Max)
Central Heating (Min)
Hot Water
Boiler input "Q"
Net CV
kW
24.3
6.1
30.4
Gross CV
kW
27
6.7
33.7
Gas Consumption
Yes
I/s
0.698
0.173
0.871
Non condensing (70C mean water temperature)
kW
24.2
6.1
Condensing (40C mean water temperature)
kW
25.2
6.4
Seasonal Efficiency
SEDBUK
Band A
91.10%
NOx classification
Class 5
Maximum DHW Output
kW
30.3
DHW flow rate @35C rise
I/min
12.4
DHW specific rate
I/min
14.5
Performance Data
Central Heating (Max)
Central Heating (Min)
Hot Water
Boiler input "Q"
Net CV
kW
24.3
6.1
30.4
Gross CV
kW
27
6.7
33.7
Gas Consumption
Yes
I/s
0.698
0.173
0.871
Non condensing (70C mean water temperature)
kW
24.2
6.1
Condensing (40C mean water temperature)
kW
25.2
6.4
Seasonal Efficiency
SEDBUK
Band A
91.10%
NOx classification
Class 5
Maximum DHW Output
kW
30.3
DHW flow rate @35C rise
I/min
12.4
DHW specific rate
I/min
14.5
Installation Data |
||
|
Gas Supply |
2H-G20-20mbar |
|
|
Gas supply connection |
15mm copper compression |
|
|
Injector size |
mm |
4.65 |
|
Inlet connection |
Domestic hot water |
15mm copper compression |
|
Outlet connection |
Domestic hot water |
15mm copper compression |
|
Flow connection |
Central heating |
22mm copper compression |
|
Return connection |
Central heating |
22mm copper compression |
|
Concentric flue terminal diameter |
mm |
100 |
|
Keston 50mm flue terminal diameter |
mm |
50 |
|
Average flue temperature – mass flow rate |
DHW |
|
|
Maximum working pressure – sealed systems |
bar |
2.5 |
|
Maximum domestic hot water inlet pressure |
bar |
10 |
|
Minimum domestic hot water inlet pressure |
bar |
1.3 |
|
Electrical supply |
v |
230v-50Hz |
|
Power consumption |
W |
152 |
|
Fuse rating |
External 3A Internal T4H-HRC-L250v |
|
|
Water content (central heating) |
Litre |
1.2 |
|
Water content (hot water) |
Litre |
0.5 |
|
Packaged weight |
kg |
37 |
|
Installation weight |
kg |
33 |
|
Casing height |
mm |
700 |
|
Casing width |
mm |
395 |
|
Casing depth |
mm |
278 |
|
Maximum flue length concentric |
mm |
650 |
|
Maximum flue length using twin flue |
21 metres * |