Below is the technical specification for our range of Duet heating units. Listed below this are the specification tables for the Celsius 25 and Spa cylinders.

Technical Specification 

qDuet
12
0

qDuet
150

qDuet 210

 
 
 
 
Height (mm)
1933
2120
1933
Width (mm)
600
600
600
Depth (mm)
625
625
875
Top Clearance (mm)
100
100
100
Side Clearance (mm)
25
25
25
Front Clearance, for Servicing (mm)
400
400
400
Weight, Empty (kg)
97
102
112
Weight, Full (kg)
221
256
326
Spa Water storage volume (litres)
120
150
210
Heating Flow Connection (FI)
3/4
3/4
3/4
Heating Return Connection (FI)
3/4
3/4
3/4
DHW Connection (FI)
3/4
3/4
3/4
CWS Connection (FI)
3/4
3/4
3/4
G3 D2 Pipe Size (up to 9m) (mm)
22
22
22
DHW Re-Heat Time (45C rise) (mins)
23
25
35
Gas Connection
Rp 0.5"F
Rp 0.5"F
Rp 0.5"F

 

Technical Specification

Qudos 28s

Qudos 28sP

Max. Input

k/W/(Btu/h)

29.4/(100,300)
27.8/(94,850)

Max. Output to Water

 

 
 
(80/60C Flow/Return)
k/W/(Btu/h)
26.4/(90,500)
25.5/(87,000)
(50/30C Flow/Return)
k/W/(Btu/h)
28.4/(96,900)
28.4/(96,900)
Min. Output to Water

 

 
 
(80/60C Flow/Return)
k/W/(Btu/h)
7.0/(24,900)
7.0/(24,900)
(50/30C Flow/Return)
k/W/(Btu/h)
7.8/(26,600)
7.6/(26,000)
Max. Burner Press. - Hot (factory preset)

mbar/(in w.g)

0 (0)
0/(0)
Gas Consumption After 10 Mins.

l/s / (ft³/hr)

0.76/(96.6)
0.35/(45.0)
Max. Operating Flow Temp.

°C

82.00
82.00
Max. Press. (Sealed Systems)
Bar
2.5
2.5
Inlet Gas Pressure

mbar/(in w.g)

20.0/(8.0)
37.0/(14.8)
Recommended Temperature Differential

°C

8 to 20
8 to 20
Electrical Supply

 

230V 50Hz
230V 50Hz
Power Consumption - inc. pump (Max)

W

150
150
Gas Connection
 
Rp 0.5" F
Rp 0.5" F
Condensate Connection
 
 22mm plastic overflow
Flue Pipe (nominal bore)
mm/(in)
 50/(2)
50/(2)
Air Intake Pipe Size (nominal bore)
 
 50/(2)
50/(2)
Flue and Air Intake Material
 
  muPVC (BS5255)/BSEN
1566-18BSEN1329
Max. Air Intake length
m
 39
39
Max. Flue Outlet Length
m
 20
20
Max. Total Outlet and Air Intake Length
m
 40
40
Type of Gas
 
G20 Natural Gas
G31 LPG  
Optimum Flue Gas CO2 Level
%
9.1
10.5
Destination Countries
 
GB / IE
GB / IE
SEDBUK Efficiency
Band / %
A / 91.1
A / 92.9
British Gas GC no.
 
41 930 17
41 930 18

 

Technical Specification

qSpa 120

qSpa 150

qSpa 210

Immersion Heater Output

kW

3
3
3
Heat-up Time 15-65 °C

mins*

23
25
35
Re-Heat Time

mins**

17
17
22
Nominal Size

mm

906 x 550
1093 x 550
1489 x 550
Stored Water Capacity

Litres

120
150
210
Weight (empty)

kg

35
40
50
Weight (full)

kg

155
190
260
Coil Flow/Return Connections

MM

22
22
22
Domestic Water Connections

 MM

22
22
22
Secondary Return Connections

 MM

N/A
N/A
22
Immersion Heater Boss

 BSP

1.5" F
1.5" F
1.5" F
Insulation Thickness

mm 

33
33
33

NB: Figures are for guidance only and are based on BS6700 recommendations. *Heat-up from 15 to 65 °C with constant 82 °C coil flow temperature. ** Reheat times after 70% of tank is drawn off and replaced with 15 °C water.

All units are complete with factory fitted 3kW 1.5 inch immersion heater, 30 - 70 adjustable thermostat. For a diagram showing the main dimensions of the Duet click here.

 

 
""

KESTON Boilers Limited, 34 West Common Road, Hayes, Bromley, Kent BR2 7BX, United Kingdom, Telephone: 020 8462 0262 Fax: 020 8462 4459 General Information: info@keston.co.uk