Keston Boilers

Tel: (+44) 020 8462 0262

Email: info@keston.co.uk

 
""
""
""
""
 

support information

keston qudos

The section below details the performance data for the Keston Qudos range.

 Physical Data

Qudos 28h and 28hP
Qudos 28s and 28sP
Qudos Duet 120/150/210
Qudos Solar Duet 210
Cabinet Height
mm
680
700
1780
2050
Cabinet Width
mm
390
435
625
625
Cabinet Depth
mm
280
280
915
915
Top Clearance
mm
150
150
150
150
Side Clearance
mm
5
5
5
5
Base Clearance
mm
200
200
N/A
N/A
Front Clearance (for servicing)
mm
300
300
300
300
Weight - Full
kg/(lbs)
39/(86)
47/(104)
261/296/373
408
Weight - Empty
kg/(lbs)
35/(77)
43/(95)
121/126/137
154
Flow and Return Connection  

G3/4
G3/4
22mm
22mm
DHW and CWS Connection  

N/A
N/A
22mm
15mm
Gas Connection

G1/2
G1/2
G1/2
G1/2
Condensate Connection Overflow  

22mm plastic
22mm plastic
22mm plastic
22mm plastic
Safety Valve Connection Discharge  

15mm copper
15mm copper
 22mm (D2)
22mm (D2)
IP Rating  

IP20 (IPX0)
IP20 (IPX0)
IP20 (IPX0)
IP20 (IPX0)
Flue and Air Intake Material : 50mm muPVC (BS5255)/BSEN1566-1 (pipe) & BSEN1329 (fittings)  
Max. Flue Outlet Length
m
20
20
20
20
Max. Total Flue Outlet and Air Intake Length
m
40
40
40
40
Flue and Air Intake Material : 75mm Keston Composite    
Max. Flue Outlet Length
m
60
60
60
60

Max. Total Flue Outlet and Air Intake Length
m
120
120
120

120
 
Performance Data

Qudos 28h and 28hP
Qudos 28s and 28sP
Qudos Duet 120/150/210
Qudos Solar Duet 210
Max. CH Input (Gross CV)
kW/(Btu/h)
29.4/(100,300)
27.8/(94,850)
29.4/(100,300)
27.8/(94,850)
Max. Output to Water (80/60C Flow/Return)
kW/(Btu/h)
26.4/(90,500)
25.5/(87,000)
26.4/(90,500)
25.5/(87,000)
Max. Output to Water (50/30C Flow/Return)
kW/(Btu/h)
28.4/(96,900)
28.4/(96,900)
28.4/(96,900)
28.4/(96,900)
Min. Output to Water (80/60C Flow/Return)
kW/(Btu/h)
7.0/(24,900)
7.8/(26,600)
7.0/(24,900)
7.8/(26,600)
Max Gas Cons After 10 mins
l/s/(ft3/hr)
0.76/(96.6)
0.35/(45.0)
0.76/(96.6)
0.35/(45.0)
Max Operating Flow Temp.
C
82
82
82
82
Max Pressure (Sealed System)
bar
2.5
2.5
2.5
2.5
Inlet Gas Pressure
mbar/(in wg)
20.0/(8.0)
20.0/(8.0)
20.0/(8.0)
20.0/(8.0)
Electrical Supply

230V 50Hz
230V 50Hz
230V 50Hz
230V 50Hz
Power Consumption (Max)
W
84
84
150
150
Power Consumption (Standby)
W
8.5
8.5
8.5
8.5
Type of Gas  

G20 Nat
Gas G31 LPG
G20 Nat Gas
G31 LPG
Optimum Flue Gas CO2 Level (at max rate, case on)
%
9.1
10.5
9.1
10.5
SEDBUK Efficiency*
%
91.1 (A)
93.1 (A)
91.1 (A)
93.1 (A)
NOx Class

5
5
5
5
Safety Valve bar/(lbf/sq in)

N/A
N/A
3/(43.5)
3/(43.5)
Expansion Vessel Capacity litre

N/A
N/A
8
8
Expansion Vessel Charge Pressure bar/(lbf/sq in)

N/A
N/A
1.0/(14.5)
1.0/(14.5)
GC Number

41-930-19
41-930-20
41-930-17
41-930-18
CE PI Number

87BR36
87BR36
87BR36
87BR36
*Subject to confirmation

 

 

 

 
""

KESTON Boilers Limited, 34 West Common Road, Hayes, Bromley, Kent BR2 7BX, United Kingdom, Telephone: 020 8462 0262 Fax: 020 8462 4459 General Information: info@keston.co.uk
Designed and built by PRG.